The rising sophistication of emergency lighting systems means that as properly as being a significant a half of a building’s life safety infrastructure they can additionally save money and scale back CO2 emissions thanks to the advantages clever LED-based options with superior battery technology have over traditional methods.
Anyone who has had the misfortune of being in an unfamiliar building when a hearth alarm is activated or a primary lighting failure has occurred will understand the true worth of an emergency lighting system. Although we regularly take these familiar green and white signs as a right, emergency lighting’s role, as a half of an general life security system, ought to by no means be underestimated. Recent years have witnessed vital advancements in the expertise deployed in these techniques, with the result that they now provide a stage of intelligence that mixes energy effectivity with reliability and ease-of-use.
Bad Behaviour

The way by which we use power is constantly in the spotlight and if further proof was required of the necessity for all of us to handle our behaviour it came in a 2013 report by the Intergovernmental Panel on Climate Change (IPCC). It stated that scientists are 95 p.c certain that we are the ‘dominant cause’ of world warming for the explanation that Fifties.
This might not come as much of a shock. However, by way of greater awareness of the results of CO2, mixed with the financial implications of rising utility bills, organisations are more willing and ready than ever to use power correctly. Growing laws and regulation implies that companies all over the world are implementing power discount measures. The focus is usually on adopting renewable energy technologies such as photo voltaic photovoltaics (PV), wind generators and ground and air source warmth pumps as methods to generate power, whereas others are utilizing constructing management systems (BMS) to gain a holistic view of their energy use and identify methods to lower their consumption.
However, the strain is on to do much more, which is why building homeowners and managers are having to drill down and take a look at individual parts of their constructing companies infrastructures to see whether there any further financial savings may be made.
Light Years Ahead

Modern emergency lighting techniques offer the chance for vital energy and price financial savings. This is due to two key factors – the usage of mild emitting diode (LED) based lighting and superior battery know-how.
Traditional emergency lighting methods utilise crude nickel cadmium, nickel metallic hydride or lead acid batteries. They drive the centrally operated system by continually charging, discharging somewhat after which recharging – a course of that uses unnecessary amounts of energy and quickly decreases the lifecycle of the battery. It means that battery life is restricted to between one and four years, dependent upon the appliance.
State-of-the-art intelligent expertise, however, utilises only the quantity of energy needed to fully cost the emergency lighting batteries, and then shuts the battery down until an emergency situation happens. This avoids degradation, prolongs life and reduces vitality consumption. Some techniques are also obtainable with luminaires which would possibly be geared up with integral batteries permitting continued operation for a minimal of three hours, even in circumstances where the management panel or energy cables are damaged. Maintained luminaires may be powered immediately from the road in order not to affect any battery capability due to this fact leaving the batteries in an “always ready” state.
So what type of power savings could be made as a result? It is estimated that intelligent battery methods use between five and ten p.c power of that a traditional battery system would use. Consider larger installations of up to 5,000 luminaires – which are not uncommon in hospitals, for instance – and the financial savings soon turn out to be obvious.
Bright Spark

It is estimated that lighting accounts for greater than 19 percent of the world’s complete electricity consumption. According to Green LED Solutions, if solely half of worldwide lighting was converted to LED by 2025, power use can be reduce by 120GW, saving £66 billion a year and decreasing CO2 emissions from energy crops by 350Mt over the identical interval.
LED lighting has seen rapid adoption and the global market was value $25.4 billion in 2013, according to a Digitimes Research Special Report. LED expertise is both price effective and environmentally friendly, making it a greener different to other systems which might be at present out there and permitting operating costs to be saved to a minimum with out compromising effectivity.
LED technology is now being utilized in emergency lighting methods and these new luminaires supply some spectacular financial savings. For occasion, they devour less than 0.5W, while an identical 8W fluorescent mild exit luminaire will use approximately 12W. These methods additionally include further energy saving features, including signage that’s related by way of low voltage 40V cabling, which is powered and configured on the identical loop by way of a single panel, giving high ranges of management via an computerized system.
Testing Times

All emergency lighting systems have to be examined on a month-to-month basis in compliance with BS EN 50172. The test itself normally entails flicking a guide change, which interrupts the ability provide to the luminaire, so that it illuminates. A full record sheet needs to be maintained for each emergency luminaire and entered into a logbook, which should be out there for inspection by the authorities at any time. pressure gauge 10 bar to offer full check data may end up in legal motion and closure of the building, and if the emergency lighting is flawed, the insurance coverage coverage for the constructing may be invalid.
On the floor this all seems cheap and fulfils the requirements of the Standard, nevertheless, the testing process itself is flawed and doesn’t essentially result in a secure and fully functional system. All it does is examine that the system works for a couple of seconds when the guide swap is operated – what occurs if the system fails 5 minutes after the test? It won’t be retested for an additional month, so may depart a building’s occupants susceptible in the meantime.
Also, it doesn’t take a look at just for how lengthy the luminaires will keep on and whether the battery has sufficient energy to maintain operation for the period specified within the relevant standards. The time required to evacuate the premises is determined by its measurement and complexity. The duration itself depends not solely on evacuation time but additionally on whether or not the premises are evacuated immediately the power and normal lighting fails and/or are reoccupied instantly the availability is restored.
BS EN 50172 states the minimum period of an emergency lighting system as one hour. However, a minimal period of three hours should be used for emergency lighting if the premises are not evacuated immediately, as in the case of sleeping lodging, for instance, or if the premises will be reoccupied instantly the availability is restored without ready for the batteries to be recharged. It should also be famous that to comply with the National Fire Protection Association (NFPA) 101 Life Safety Code, emergency lights are required to remain lit for 90 minutes.
Modern emergency lighting management panels constantly monitor and take a look at functionality in real time. They can be pre-programmed to carry out particular month-to-month, six month-to-month and annual tests and it’s also possible to set operational parameters as much as alert when batteries are at 85 percent capability, providing a excessive level of reassurance that the system will work accurately underneath all circumstances.
FACTS OF THE MATTER

Lighting consumes 19 % of all electrical energy on the planet.
The first LED device was crafted in 1907 by Captain H J Round, a British radio know-how pioneer and a personal assistant to Guglielmo Marconi.
Nick Holonyak Jr is considered ‘the father of the fashionable LED’. In 1962, whereas working at General Electric, he developed the first virtually useful visible spectrum LED device for commercial use.
In 2009, a typical 13W LED lamp emitted 450-650 lumens, which is equal to a normal 40W incandescent bulb. LEDs have become extra efficient, in order that now a 6W LED can simply obtain the identical outcomes.
LEDs produce a protracted service life of between 50,000 hours and one hundred,000 hours. This compares with 2,000-5,000 hours for a halogen bulb and eight,000 hours to 15,000 hours for a compact fluorescent lamp (CFL).
Unlike CFLs LEDs do not contain mercury and can be more safely disposed of.
LEDs emit no ultraviolet radiation (UV) or infrared (IR), which makes them good to illuminate costly objects corresponding to images, collections, paintings and so on.
LEDs produce more mild than warmth, which makes them the safest type of lighting and reduces the chance of fires.
Right Place, Right Time

Evacuation is usually hindered by a lack of detailed information of the internal connectivity of the constructing area, together with confusing and poorly thought out directions. Studies have also proven that in these conditions occupants often make use of familiar routes – usually using the exit through which they entered the constructing. Even extra worryingly, research from the University of Greenwich, as a half of its research known as Human Behaviour in Fire Network (HUBFIN), discovered that only 38 % of individuals see passive signage in an emergency. This is a daunting statistic and only serves to spotlight the significance of siting an emergency lighting system in a method that may guide folks to a safe location within the occasion of a mains lighting failure.
BS EN 50172 provides steerage on the positioning of luminaires, supplies a minimal normal that ought to be applied and offers guidance on particular hazards and factors of emphasis that should be accounted for. Points of emphasis are necessary places where lighting should highlight specific hazards, security tools and indicators. These embrace areas near stairs, near adjustments of stage, at every change of course, close to firefighting equipment and manual call points, outside and close to to each final exit, first help factors, at exit doorways, and close to safety indicators.
Signs are both internally of externally illuminated and the utmost viewing distances for internally illuminated signs is 200 instances the panel peak, and 100 times the panel height for externally illuminated indicators. Luminaires should offer 1Lux of output in escape routes and 0.5Lux in open areas. Emergency lighting must also be positioned in such a means to make sure that people are free from incapacity glare, which can stop obstructions or signs from being correctly seen.
It is price remembering that Industry Committee for Emergency Lighting (ICEL) accredited products are independently examined and meet the present product and utility standards. Therefore, selecting products with ICEL approval will provide reassurance of compliance.
Look to the Future

The issues with passive signage are clear from the University of Greenwich’s HUBFIN analysis, which is why the mixing of fireside detection and emergency lighting methods is the subsequent step in adding intelligence and larger effectiveness to a life safety infrastructure.
A conventional emergency lighting system does not permit signs to be ‘shut off’, which may enable individuals to unwittingly travel into the path of hazard. In locations corresponding to hospitals and care houses, where people usually have restricted mobility, time is of the essence and must not be wasted by having to decipher probably the most appropriate escape route.
By integrating a fire detection system with emergency lighting, and by identifying the place a fireplace is taking place, the right route may be configured and communicated. For example, by responding to information sent from the fireplace detectors it is attainable to put a purple ‘X’ on specific emergency luminaires, which indicators to folks to not exit through that particular route. This may also be synchronised with the existing PA/VA system, adding another level of safety.
Not only does integration make good sense from a security point of view, it has a selection of cost saving and environmental advantages. It is estimated that it may reduce the complete system’s wiring content material by 75 %, as there can be just one loop with both functions.
Feature Packed

A correctly specified, put in and maintained emergency lighting system is essential in order to give occupants a way of evacuating a building safely within the occasion of a mains lighting failure, or if required, a fireplace. The rules, standards and steerage on this topic are complete and the advanced LED lighting and battery expertise that’s now out there combines reliability, functionality and usefulness with one other method to save power.
Share